Normal Duty |
Heavy Duty |
|
Typical Motor Power |
Continuous Output
Current |
Max. Output Current |
Typical Motor Power |
Continuous Output
Current |
Maximum Output
Current |
|
Model Reference |
Frame Size |
Supply Voltage &
Motor Power Rated Voltage |
(kW) |
(hp) |
In (A) |
Open Loop (A) |
(kW) |
(hp) |
In (A) |
Open Loop (A) |
Closed Loop (A) |
|
SP1201 |
1 |
200 to 240V
± 10%
kW at 220V
hp at 230V |
1.1 |
1.5 |
5.2 |
5.7 |
0.8 |
1.0 |
4.3 |
6.5 |
7.5 |
|
SP1202 |
1.5 |
2.0 |
6.8 |
7.5 |
1.1 |
2.0 |
5.8 |
8.7 |
10.2 |
|
SP1203 |
2.2 |
3.0 |
9.6 |
10.6 |
1.5 |
2.0 |
7.5 |
11.3 |
13.1 |
|
SP1204 |
3.0 |
3.0 |
11.0 |
12.1 |
2.2 |
3.0 |
10.6 |
15.9 |
18.6 |
|
SP2201 |
2 |
4.0 |
5.0 |
15.6 |
17.1 |
3.0 |
3.0 |
12.6 |
18.9 |
22.1 |
|
SP2202 |
5.5 |
7.5 |
22.0 |
24.2 |
4.0 |
5.0 |
17.0 |
25.5 |
29.8 |
|
SP2203 |
7.5 |
10.0 |
28.0 |
30.8 |
5.5 |
7.5 |
25.0 |
37.5 |
43.8 |
|
SP3201 |
3 |
11.0 |
15.0 |
42.0 |
46.2 |
7.5 |
10.0 |
31.0 |
46.5 |
54.3 |
|
SP3202 |
15.0 |
20.0 |
54.0 |
59.4 |
11.0 |
15.0 |
42.0 |
63.0 |
73.5 |
All Unidrive SP
modules have optional footprint filters for applications not met
with standard on board filters |